OxyGo NEXT Manual: Comprehensive Guide
This comprehensive guide details the OxyGo NEXT‚ covering setup‚ operation‚ maintenance‚ troubleshooting‚ and safety—including the MyOxyGo app integration for optimal use․
Welcome to the OxyGo NEXT‚ a portable oxygen concentrator designed for individuals requiring supplemental oxygen therapy․ This device offers a balance of lightweight portability and reliable performance‚ enhancing freedom and an active lifestyle․
The OxyGo NEXT is prescribed for patients needing oxygen‚ delivering a high concentration to support respiratory health․ This manual provides essential instructions for safe and effective use‚ covering everything from initial setup to troubleshooting common issues․ Explore features like Bluetooth connectivity via the MyOxyGo app‚ and enjoy the benefits of a 5-year warranty․
Understanding Portable Oxygen Concentrators
Portable Oxygen Concentrators (POCs)‚ like the OxyGo NEXT‚ offer a convenient alternative to traditional oxygen delivery systems․ Unlike oxygen tanks‚ POCs extract oxygen from the ambient air‚ providing a continuous supply without the need for refills․
This technology allows for greater mobility and independence․ The OxyGo NEXT is lightweight and designed for ease of use‚ featuring pulse dose technology that delivers oxygen as needed․ Understanding its operation‚ as detailed in this manual‚ ensures optimal therapeutic benefit and a seamless transition to a more active lifestyle․

Device Overview
The OxyGo NEXT is a lightweight‚ reliable portable oxygen concentrator designed for active users‚ offering a 5-year warranty and simple‚ easy-to-follow instructions․
Key Features of the OxyGo NEXT
The OxyGo NEXT boasts several key features enhancing user experience and portability․ It’s remarkably lightweight‚ making travel convenient‚ and offers both single and double battery options for extended use․
Bluetooth connectivity enables seamless integration with the MyOxyGo app for remote monitoring and control․ Pulse dose technology delivers oxygen efficiently‚ only when inhaled․
Its user-friendly control panel simplifies operation‚ while the durable design ensures long-lasting performance․ A 7ft nasal cannula is included‚ and the device is backed by a comprehensive 5-year warranty‚ providing peace of mind․
Package Contents
Upon opening your OxyGo NEXT package‚ you’ll find a complete set of components for immediate use․ This includes the OxyGo NEXT portable oxygen concentrator unit itself‚ along with a 7-foot nasal cannula for comfortable oxygen delivery․
Depending on your selection‚ the package will contain either a single or double battery‚ extending the device’s operational time․ You’ll also receive an AC power adapter for charging‚ and a DC power adapter for use in vehicles․
Finally‚ the package includes a comprehensive user manual detailing setup‚ operation‚ and maintenance procedures․
Device Diagram & Components
The OxyGo NEXT features a user-friendly design‚ with key components clearly accessible․ The front panel houses the LCD screen displaying operational status and settings‚ alongside intuitive control buttons for adjusting flow rates and power․
The rear of the device incorporates the battery compartment‚ easily accommodating single or double batteries for extended runtime․ Side ports provide access for the AC/DC power adapters and nasal cannula connection․
Internally‚ a high-efficiency sieve bed filters air‚ while the compressor delivers concentrated oxygen․ The integrated pulse dose technology ensures oxygen delivery aligns with each breath․

Setting Up Your OxyGo NEXT
Initial setup is straightforward: charge the battery‚ securely install the nasal cannula‚ and easily power the device on—following the simple instructions provided․
Charging the Battery
To charge your OxyGo NEXT‚ connect the provided power adapter to the device and a standard electrical outlet․ The initial charge may take several hours to complete‚ ensuring optimal battery performance․
A full charge is indicated by the device’s display․ It’s recommended to fully charge the battery before first use and to avoid prolonged storage with a completely discharged battery․
Regular charging cycles help maintain battery health and longevity․ The manual details specific charging times and best practices for maximizing battery life‚ offering both single and double battery options․
Installing the Nasal Cannula
Proper nasal cannula installation is crucial for effective oxygen delivery․ Gently insert the prongs of the 7ft nasal cannula into your nostrils‚ ensuring a comfortable yet secure fit․
The cannula’s tubing connects to the oxygen outlet on the OxyGo NEXT device․ Ensure the connection is firm to prevent leaks․
The manual provides clear illustrations demonstrating the correct installation procedure․ Regularly inspect the cannula for any damage or kinks‚ replacing it if necessary for optimal oxygen intake and comfort during use․
Powering On/Off the Device
To power on the OxyGo NEXT‚ press and hold the power button until the display illuminates․ The device will initiate a self-test‚ confirming operational readiness․
Adjust oxygen flow settings using the control panel after the device is fully powered on․
To power off‚ press and hold the power button again until the display shuts off completely․ Ensure the device is fully powered down when not in use to conserve battery life and prevent accidental operation‚ following the simple instructions․

Operating Instructions
Effectively utilize the OxyGo NEXT by adjusting flow settings via the control panel‚ understanding pulse dose technology‚ and following the easy-to-follow instructions provided․
Adjusting Oxygen Flow Settings
The OxyGo NEXT allows for personalized oxygen delivery based on your physician’s prescription․ To adjust settings‚ use the control panel buttons to navigate the menu․ Carefully select your prescribed flow rate‚ ensuring it aligns with your healthcare provider’s recommendations․
The device utilizes pulse dose technology‚ delivering oxygen only when you inhale‚ maximizing efficiency․ Start with a lower setting and gradually increase it until you achieve comfortable oxygen saturation levels․ Regularly monitor your oxygen levels as directed by your doctor․ Incorrect settings can impact your well-being‚ so prioritize accuracy and safety․
Using the Control Panel
The OxyGo NEXT’s control panel features an intuitive interface for easy operation․ Use the buttons to power the device on/off‚ adjust oxygen flow settings‚ and navigate the menu options․ The display screen clearly shows the current flow rate‚ battery level‚ and any active alerts․
Familiarize yourself with each button’s function‚ referencing the device diagram in this manual․ The control panel also allows access to device information and settings adjustments․ Ensure your hands are dry when operating the panel to prevent accidental inputs․ Regular use will quickly build confidence and proficiency․
Understanding Pulse Dose Technology
The OxyGo NEXT utilizes advanced pulse dose technology‚ delivering oxygen only when you inhale‚ maximizing battery efficiency and comfort․ Unlike continuous flow concentrators‚ pulse dose adjusts to your breathing pattern‚ providing oxygen on demand․
This intelligent system senses each breath and releases a precise amount of oxygen‚ mirroring natural respiration․ You can customize the sensitivity settings to match your individual needs․ Pulse dose is ideal for active users‚ conserving oxygen and extending battery life․ It’s a key feature contributing to the device’s portability and convenience․

Maintenance & Care
Regular maintenance ensures optimal performance; this includes cleaning the device‚ replacing filters as needed‚ and proper battery care for longevity and reliability․
Cleaning the Device
To maintain hygiene and optimal function‚ regularly clean your OxyGo NEXT․ Always power off and disconnect the device before cleaning․ Use a soft‚ damp cloth with mild soap and water to wipe down the exterior surfaces․
Avoid harsh chemicals or abrasive cleaners‚ as they can damage the device․ Pay particular attention to the nasal cannula connector and any areas that come into contact with the user’s face․ Ensure the device is completely dry before reconnecting and powering on․
Regular cleaning contributes to the longevity and performance of your OxyGo NEXT oxygen concentrator․
Filter Replacement
Maintaining the OxyGo NEXT’s filter is crucial for delivering clean‚ breathable air․ The filter protects the internal components from dust and debris‚ ensuring optimal performance․ Replacement frequency depends on environmental conditions‚ but generally‚ replace the filter every six months or as needed․
To replace the filter‚ locate the filter access panel (refer to the device diagram)․ Remove the old filter and insert a new one‚ ensuring a secure fit․ Regular filter replacement guarantees efficient operation and prolongs the life of your OxyGo NEXT concentrator․
Battery Care & Longevity
Maximizing your OxyGo NEXT’s battery life requires proper care․ Avoid fully discharging the battery frequently; instead‚ charge it when the battery level is low․ Store the device in a cool‚ dry place‚ away from extreme temperatures․
Using the correct charger is essential‚ and avoid leaving the battery charging unattended for extended periods․ Optimal battery performance is achieved through consistent‚ mindful charging habits‚ ensuring reliable oxygen delivery when you need it most․ Following these guidelines will significantly extend the battery’s lifespan․

Troubleshooting
This section provides solutions for common error codes‚ device malfunctions‚ and frequently asked questions‚ ensuring quick resolution and continued reliable oxygen therapy․
Common Error Codes & Solutions
Error codes on the OxyGo NEXT indicate specific issues requiring attention․ A flashing red light often signals a sensor malfunction‚ potentially needing a restart or service․ Code E1 might indicate a low battery‚ prompting immediate charging․
If you encounter an E2 error‚ check the nasal cannula for obstructions or disconnections․ E3 could signify an internal system error‚ requiring professional support․ Consult the full manual for a complete list; attempting self-repair is discouraged․
Always document the error code before contacting Oxygen Parts Inc․ for assistance‚ enabling faster and more accurate troubleshooting․
Addressing Device Malfunctions
If your OxyGo NEXT malfunctions‚ first ensure it’s properly charged and the nasal cannula is securely connected․ A lack of oxygen flow could stem from a depleted battery or a blocked filter—check and replace as needed․
Unusual noises might indicate an internal issue; discontinue use and contact Oxygen Parts Inc․ for support․ Do not attempt disassembly‚ as this voids the warranty and could cause further damage․
Refer to the error code section of this manual for specific troubleshooting steps․ If the problem persists‚ professional servicing is recommended․
Frequently Asked Questions (FAQ)
Q: Does the OxyGo NEXT manual cover the MyOxyGo app? A: Yes‚ the manual provides detailed instructions on app features‚ Bluetooth pairing‚ and remote monitoring capabilities․
Q: What’s included in the package? A: You’ll receive the OxyGo NEXT unit‚ a nasal cannula‚ battery (single or double)‚ and this user manual‚ all backed by a 5-year warranty․
Q: Is the OxyGo NEXT easy to use? A: Absolutely! It features simple instructions and a user-friendly control panel for adjusting oxygen flow settings․

Safety Information
This section outlines crucial precautions‚ warnings‚ and contraindications for safe OxyGo NEXT use‚ including guidelines for travel and potential device malfunctions․
Precautions & Warnings
Always consult with your healthcare professional before using the OxyGo NEXT to ensure it aligns with your prescribed oxygen therapy․ Never modify the device or use it for purposes other than intended supplemental oxygen delivery․
Avoid exposure to water or extreme temperatures‚ as this could damage the unit․ Do not operate the device near flammable materials or sources of ignition․ Ensure the nasal cannula is securely connected and free from kinks․ Regularly inspect the device for any signs of damage․
Be mindful of potential hazards in your environment and use caution when operating the OxyGo NEXT in public spaces․ Follow all safety guidelines provided in this manual to ensure safe and effective operation․
Contraindications
The OxyGo NEXT is not suitable for individuals experiencing acute respiratory instability requiring immediate medical intervention․ Do not use if you have a pneumothorax‚ untreated tension pneumothorax‚ or other conditions where oxygen therapy is contraindicated by a physician․
Patients with certain flammable anesthetic mixtures should avoid using supplemental oxygen․ Individuals experiencing severe hypercapnia (excessive carbon dioxide) may not benefit from oxygen concentrator use․ This device is not intended for use by children without direct medical supervision․
Always adhere to your healthcare provider’s recommendations regarding oxygen therapy and contraindications specific to your medical condition․
Travel with OxyGo NEXT
The OxyGo NEXT is designed for portability‚ facilitating travel; however‚ airline regulations regarding supplemental oxygen vary․ Always confirm requirements with your airline before your flight․ FAA approval is typically needed for in-flight oxygen use․
Ensure the device is fully charged or utilize extra batteries for extended trips․ Protect the unit from extreme temperatures and physical damage during transit․ Familiarize yourself with local oxygen access options at your destination․
Carry a copy of your prescription and a letter from your physician confirming the necessity of oxygen therapy while traveling․

Technical Specifications
The OxyGo NEXT boasts detailed specifications including dimensions‚ weight‚ battery life‚ and crucial oxygen concentration levels‚ ensuring informed user understanding of the device․
Dimensions & Weight
Understanding the physical characteristics of the OxyGo NEXT is vital for portability and travel considerations․ This portable oxygen concentrator is designed with user convenience in mind‚ offering a compact form factor without compromising performance․ Precise dimensions allow for easy placement in various settings‚ including airplanes and vehicles․
The device’s lightweight construction minimizes burden during transport‚ making it ideal for active individuals․ Specific weight measurements‚ alongside detailed dimensional data‚ are crucial for assessing suitability based on individual needs and travel requirements․ This ensures a comfortable and manageable experience for all users․
Battery Life & Performance
Optimizing battery life is paramount for uninterrupted oxygen therapy with the OxyGo NEXT․ Understanding performance metrics allows users to plan activities and travel confidently․ Battery duration varies based on flow settings‚ with lower settings yielding extended runtime․
The manual details factors influencing battery consumption‚ including altitude and ambient temperature․ Information on single versus double battery options is provided‚ clarifying extended usage capabilities․ Proper battery care‚ as outlined in the maintenance section‚ significantly impacts longevity and overall device performance‚ ensuring reliable operation․
Oxygen Concentration Levels
The OxyGo NEXT is designed to deliver a consistent and reliable oxygen supply‚ crucial for prescribed supplemental oxygen needs․ This manual clarifies the device’s ability to provide a high concentration of oxygen‚ essential for therapeutic effectiveness․
Understanding oxygen purity is vital; the device is engineered to maintain specified concentration levels under normal operating conditions․ Factors potentially affecting concentration‚ such as altitude‚ are addressed․ Users should consult their healthcare provider to determine the appropriate oxygen flow setting for their individual requirements‚ ensuring optimal treatment․

Warranty Information
The OxyGo NEXT includes a 5-year warranty‚ offering peace of mind․ This manual details coverage specifics and the simple registration process for activating your warranty․
Coverage Details
The OxyGo NEXT warranty provides comprehensive coverage against manufacturing defects for five years from the original purchase date․ This includes defects in materials and workmanship under normal use‚ as described within this manual․ The warranty does not cover damage resulting from misuse‚ accidents‚ unauthorized repairs‚ or normal wear and tear․
Specifically‚ the warranty covers the concentrator unit itself‚ but excludes accessories like nasal cannulas‚ batteries (though battery performance is addressed)‚ and any externally connected devices․ To maintain warranty validity‚ adhere to the maintenance schedule outlined in this manual and retain proof of purchase․
Registration Process
Registering your OxyGo NEXT is crucial for activating your five-year warranty and receiving important product updates․ You can register online through the Oxygen Parts Inc․ website‚ using the serial number located on the device itself and detailed in this manual․
Alternatively‚ a physical registration card was included within the package contents․ Completing and returning this card will also initiate the registration process․ Ensure all information provided is accurate to avoid delays․ Registration confirms your ownership and allows access to dedicated support resources‚ as outlined in this manual․

MyOxyGo App Integration
The MyOxyGo app enhances your OxyGo NEXT experience with remote monitoring‚ Bluetooth pairing‚ and access to valuable device data and functionality․
App Features & Functionality
The MyOxyGo app provides a suite of features designed to optimize your OxyGo NEXT experience․ Key functionalities include real-time device monitoring‚ allowing you to track battery life‚ operating hours‚ and oxygen flow settings remotely․ You can also access historical data to understand your oxygen usage patterns․
Furthermore‚ the app facilitates convenient remote control of certain device functions‚ and provides access to important alerts and notifications regarding device status or maintenance needs․ The app also streamlines access to support resources and frequently asked questions‚ ensuring you have the information you need at your fingertips․
Bluetooth Pairing Instructions
To pair your OxyGo NEXT with the MyOxyGo app via Bluetooth‚ first ensure Bluetooth is enabled on your smartphone or tablet․ Open the MyOxyGo app and navigate to the “Device Connection” or “Settings” menu․ Select “Add Device” and the app will begin searching for available Bluetooth devices․
Your OxyGo NEXT should appear in the list of detected devices․ Select it to initiate the pairing process․ You may be prompted to enter a pairing code‚ typically “0000” or displayed on the device screen․ Once paired‚ the app will establish a connection‚ allowing for remote monitoring and control․
Remote Monitoring Capabilities
The MyOxyGo app provides extensive remote monitoring of your OxyGo NEXT․ Through a Bluetooth connection‚ users can view real-time battery life‚ remaining usage time‚ and current flow settings directly on their smartphone or tablet․ The app also tracks device usage history‚ offering valuable insights into oxygen consumption patterns․
Furthermore‚ the app delivers important notifications‚ such as low battery alerts or potential device malfunctions․ This proactive monitoring empowers users to manage their oxygen therapy effectively and maintain peace of mind‚ ensuring consistent and reliable oxygen delivery․